Changes for page 2.3.1 Residential building quality
Last modified by Hyunji Cho on 2022/04/06 13:05
From version 1.1
edited by Hyunji Cho
on 2022/02/28 11:50
on 2022/02/28 11:50
Change comment:
There is no comment for this version
To version 9.1
edited by Hyunji Cho
on 2022/03/01 13:08
on 2022/03/01 13:08
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -2.1. 4ResidentialBuilding quality& space1 +2.1.1 Residential building quality - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= 2.1. 4ResidentialBuilding quality& space=1 += 2.1.1 Residential building quality = 2 2 3 3 |((( 4 4 ====== **Social challenge/ impact linked to:** ====== ... ... @@ -25,13 +25,14 @@ 25 25 )))|((( 26 26 27 27 28 -* City 29 -* Neighborhood 28 +* Building 30 30 ))) 31 31 |((( 32 32 ====== **Data source and input type** ====== 33 33 )))|((( 34 -* Building energy efficiency 33 +* The age of the building (using secondary data) 34 +* Building energy efficiency (using secondary data or survey) 35 +* Indoor air quality (Estimation from outdoor air quality or measurement) 35 35 * Building location 36 36 ))) 37 37 |((( ... ... @@ -45,26 +45,40 @@ 45 45 |((( 46 46 ====== **Required Data** ====== 47 47 )))|((( 48 -* Energy efficiency 49 +* Energy efficiency (using secondary data or survey) 50 +* Building energy efficiency 51 +* Indoor air quality 52 +* Building location 49 49 ))) 50 50 |((( 51 51 ====== **Expected Outputs** ====== 52 52 )))|((( 53 53 * Annual measurements 54 -* The score of the energyefficiency58 +* The score of the building quality 55 55 ))) 56 56 |((( 57 57 ====== **Calculation methods** ====== 58 58 )))|((( 59 59 * The area is divided into buildings, groups of buildings or blocks that represent similar building stock, as seen suitable. Each component is assessed on its environmental design considering incorporated environmental design considering parameters listed in Table 1. The building(s) being assessed are scored from 0 to 1 with respect to each parameter. 60 -* Parameter: Energy efficiency 61 -* Methods to consider (examples): Improved insultation/ Reflecting windows, Improved ventilation/ Heat excahngers in ventilation/Smart lighting, smart eletronics/ Renewable electricity (solar/wind)/ Heat pumps 64 +* **Parameter: The age of the building** 65 +* Methods to consider (examples): 66 +** Existing information of the age of the buildings from the municipality 67 +* Scoring: TBC 68 +* **Parameter: Energy efficiency** 69 +* Methods to consider (examples): 70 +** Existing national energy efficiency rating - need to consider making comparable measurements over five cities 71 +** Survey on- Improved insulation/ Reflecting windows, Improved ventilation/ Heat exchangers in ventilation/Smart lighting, smart electronics/ Renewable electricity (solar/wind)/ Heat pumps 62 62 * Scoring: 0 points: No design incorporated / 0.5 points: some measures taken / 1 point: Good measures taken 73 +* **Parameter: Indoor air quality ** 74 +* Methods to consider (examples): 75 +** Estimation of indoor air quality by using outdoor air quality: using the existing research on the correlation between them 76 +** measurement on: Indoor air quality 77 +* Scoring: 0 points: No design incorporated / 0.5 points: some measures taken / 1 point: Good measures taken 63 63 ))) 64 64 |((( 65 65 ====== **Level of expertise required** ====== 66 66 )))|((( 67 -* 82 +* Depending on the methods 68 68 ))) 69 69 |((( 70 70 ====== **Links and references** ======