Changes for page 2.3.1 Residential building quality
Last modified by Hyunji Cho on 2022/04/06 13:05
From version 5.1
edited by Hyunji Cho
on 2022/02/28 13:55
on 2022/02/28 13:55
Change comment:
There is no comment for this version
To version 9.1
edited by Hyunji Cho
on 2022/03/01 13:08
on 2022/03/01 13:08
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -2.1.1 Residential Building quality& space1 +2.1.1 Residential building quality - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= 2.1.1 Residential Building quality& space=1 += 2.1.1 Residential building quality = 2 2 3 3 |((( 4 4 ====== **Social challenge/ impact linked to:** ====== ... ... @@ -25,14 +25,14 @@ 25 25 )))|((( 26 26 27 27 28 -* City 29 -* Neighborhood 28 +* Building 30 30 ))) 31 31 |((( 32 32 ====== **Data source and input type** ====== 33 33 )))|((( 34 -* Building energy efficiency 35 -* Indoor air quality 33 +* The age of the building (using secondary data) 34 +* Building energy efficiency (using secondary data or survey) 35 +* Indoor air quality (Estimation from outdoor air quality or measurement) 36 36 * Building location 37 37 ))) 38 38 |((( ... ... @@ -47,6 +47,9 @@ 47 47 ====== **Required Data** ====== 48 48 )))|((( 49 49 * Energy efficiency (using secondary data or survey) 50 +* Building energy efficiency 51 +* Indoor air quality 52 +* Building location 50 50 ))) 51 51 |((( 52 52 ====== **Expected Outputs** ====== ... ... @@ -58,14 +58,18 @@ 58 58 ====== **Calculation methods** ====== 59 59 )))|((( 60 60 * The area is divided into buildings, groups of buildings or blocks that represent similar building stock, as seen suitable. Each component is assessed on its environmental design considering incorporated environmental design considering parameters listed in Table 1. The building(s) being assessed are scored from 0 to 1 with respect to each parameter. 64 +* **Parameter: The age of the building** 65 +* Methods to consider (examples): 66 +** Existing information of the age of the buildings from the municipality 67 +* Scoring: TBC 61 61 * **Parameter: Energy efficiency** 62 62 * Methods to consider (examples): 63 -** Existing national energy efficiency rating - need to consider making comparable measurement over five cities 70 +** Existing national energy efficiency rating - need to consider making comparable measurements over five cities 64 64 ** Survey on- Improved insulation/ Reflecting windows, Improved ventilation/ Heat exchangers in ventilation/Smart lighting, smart electronics/ Renewable electricity (solar/wind)/ Heat pumps 65 65 * Scoring: 0 points: No design incorporated / 0.5 points: some measures taken / 1 point: Good measures taken 66 66 * **Parameter: Indoor air quality ** 67 67 * Methods to consider (examples): 68 -** Estimation of indoor air quality by using outdoor air quality: using the existing research on correlation between them 75 +** Estimation of indoor air quality by using outdoor air quality: using the existing research on the correlation between them 69 69 ** measurement on: Indoor air quality 70 70 * Scoring: 0 points: No design incorporated / 0.5 points: some measures taken / 1 point: Good measures taken 71 71 )))